FEATURES Housing Cylindrical thread design Housing Standard Thread size M8 x 1 Diameter Ø 8 mm Sensing range Sn 2 mm Safe sensing range Sa 1.62 mm Installation type Flush Switching frequency 4, 000 Hz Connection type Connector M8, 3-pin Output function NC Electrical wiring DC 2-wire Enclosure rating IP67 1) MECHANICS/ELECTRONICS Supply voltage 10 V DC... 30 V DC Ripple = 10 % Voltage drop = 4 V 1) = 4.5 V 2) Time delay before availability = 100 ms Hysteresis 5 %... 15 % Reproducibility = 2 % 3) 4) Temperature drift (of Sr) ± 10 % EMC According to EN 60947-5-2 Continuous current Ia = 100 mA Off-state current = 0.8 mA Minimum load current = 3 mA Short-circuit protection? Reverse polarity protection? Power-up pulse = 5 ms Shock and vibration resistance 30 g, 11 ms/10 Hz.
.. 55 Hz, 1 mm Ambient operating temperature –25 °C... +75 °C Housing material Metal, Nickel-plated brass Sensing face material Plastic, PA 66 Housing length 50 mm Thread length 34 mm Tightening torque, max. = 5 Nm UL File No. NRKH. E181493