FEATURES Sensor/ detection principle Photoelectric retro-reflective sensor, Dual lens Dimensions (W x H x D) 25 mm x 78 mm x 63 mm Housing design (light emission) Rectangular Sensing range max. 0.01 m... 15 m 1) Sensing range 0.01 m... 10 m 2) 0.01 m... 13 m 1) Type of light Visible red light Light source LED 3) Light spot size (distance) Ø 300 mm (10 m) Angle of dispersion Approx. 1.7 ° Adjustment Potentiometer, 270° MECHANICS/ELECTRONICS Supply voltage 12 V DC... 240 V DC 1) 24 V AC.
.. 240 V AC 1) Power consumption = 5 VA Switching output Relay, electrically isolated 2) Output function Change-over contacts Switching mode Light switching 2) Switching current (switching voltage) 3 A (240 V AC) 3 A (30 V DC) Response time = 20 ms Switching frequency 25 Hz 3) Connection type Cable gland Circuit protection A 4) C 5) Protection class II 6) Weight 120 g Polarisation filter? Interference emission Level EN 61000-6-3 Residential and commercial areas Housing material Plastic, ABS Optics material Plastic, PMMA Enclosure rating IP67 Items supplied Reflector P250, mounting bracket BEF-W260 Usage category AC-15, DC-13, according to EN 60947-1 Ambient operating temperature –25 °C.
.. +55 °C Ambient storage temperature –40 °C... +70 °C UL File No. EN50081-1, 242356