Single phase 16/20A 200 - 240V Auto Transfer Switch / ATS PDU. TAA Compliant.
Enables redundant A / B power option for non-redundant network devices
Built-in LX Platform Network Interface
1U horizontal rackmount; 10 outlets (8 x C13 switched / 2 x C19 unswitched)
Individually switched outlets, network interface and 2 digit visual current meter
+
+
Overview
Specs
Reviews
Learn more about the Tripp Lite PDUMH20HVATNET
Model
Brand
Tripp Lite
Model
PDUMH20HVATNET
Details
Type
Switched
Rack Size
1U
Style
Horizontal
Front Panel LEDs
8 LEDs display power on-off status for each C13 output receptacle, plus 2 additional LEDs to indicate input power status for primary and secondary inputs
Certifications
Tested to UL 60950 (USA, Canada), CE (Europe), Class A (Emissions), NOM (Mexico)
ROHS
Yes
Input
Input Voltage
200 / 208 / 230 / 240V
Maximum Input Current
20A
Input Connector(s)
IEC-320 C20
Cord Length
12 ft
Output
Output Voltage
200V, 208V, 220V, 230V, 240V
Output Frequency
50/60Hz
Output Connector(s)
8 x C13; 2 x C19
Overload Protection
8 individually switched C13 output receptacles
Environmental
Operating Relative Humidity
5 - 95%
Operating Elevation
0 - 10000 Feet
Storage Temperature
-15 to 50 Celcius degree
Feature
Features
200 - 240V 16A Automatic Transfer Switch (ATS) / Switched PDU (Power Distribution Unit)
Provides a redundant power option for critical networking equipment with a single input power cord
2 digit display reports power consumption in amps
1U horizontal rackmount form factor
10 outlets (8 x C13 switched / 2 x C19 unswitched)
Two C20 inlets for separate Primary and Secondary inputs; two 12 Feet C20 input cables included
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
ATS configurations enable hot-swappable UPS protection when used with a single UPS and redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time)
Advanced ATS configurations utilizing separate mains circuits, backup generators and separate out of phase utility power grid feeds are supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
2 - 7 millisecond transfer time
Switched outlets and ethernet interface supports individual outlet control on a real-time or programmable basis and user-specified alarm notification thresholds for all reported site power conditions