Parameter:
Standards: RS-232, RS-485, RS-422 TIA/EIA
Automatic traffic direction control, no need external flow control signal (RTS), real TXD/RXD/GND communication
Baud rate: 300bps- 115.2K bps
Allows connecting 128 sets RS-485 or RS-422 device
Transmission distance: 5, 000m(9, 600bps)
Power: 9-30VDC/350mA
Power & data flow indicator, failure detection
Working mode: asynchronous half-duplex (RS-485)
2.5KV rms/500VDC enhanced isolation, special DC/DC module, RS-485/422 provides each wire with 600W lighting, surge & ±15KV ESD protection
Connector: DB9 female to 10-pin terminal block
Transmission media: twisted-pair or shielded cable
Dimension: 117×80×25mm
Operating temperature: -40 to 85
Relative humidity: 5% to 95%
Works with all communication software, plug & play
Supports all operating system
UT-502 is an industrial level converter with optoelectronic isolation. It complies with RS-232C and RS-485 standards; it converts single side RS-232 signal to two balanced differential RS-422 or RS-485 signals. The built-in optoelectronic isolator can provide as high as 2, 500Vrm isolated voltage; the fast instant voltage restraint is designed to protect two RS-422/RS-485 interfaces; it adopts advanced TVS (TRANSIENT VOLTAGE SUPPRESSOR) instant voltage restraint; normally, TVS tube is in high impedance state; when both sides of TVS tube suffer from high power impact in a sudden, the voltage restraint will fast lower the impedance from both sides, and absorb in big current; with this, the voltage on both sides are fixed at presupposed value, protects the component of circuit from damage. This voltage restraint provides 600W each wire with lightning and ESD protection, and surge voltage and instant overvoltage protection on circuit which causing by all reasons; the tiny interelectrode capacitance ensures high speed transmission for RS-485 ports. RS-232 port connects with RS-232C standard port by DB9 female connector; RS-485 adopts 10 bits terminal block as connector.
This converter is with built-in zero delay auto receiving and transmitting conversion and unique I/O circuit auto control data flow direction without any handshake signal (RTU, DTR); there is no need jumper wire setting for half duplex (RS-485) mode, plug & play. It is compatible with current communication software and hardware, no need to set the previous working mode which base on RS-232.
UT-502 optoelectronic isolated industrial converter provides connection for point to point, point to multipoint communication. For point to multipoint mode, each converter is allowed to connect 128 sets RS-485 devices with baud rate 300- 115.2K bps. The power and data flow indicators indicate the working status.